Quality Assurance and Testing Protocols
K&K 95 Ltd. subjects each manufactured brake hose to a 100% pressure test, ensuring leak-free operation and system integrity for each piece.

Standards and compliances
Laboratory tests
According to SAE J1401:
- static pressure test
- pulse test
- cold bending (-40°C)
- fluid resistance (DOT 3 / DOT 4)
- ozone resistance
- heat aging
Geometric check
- full length
- fitting position
- thread parameters
- diameters
Traceability
- article number
- LOT number
- production date
- DOT code
- QR / barcode